{"product_id":"puma-p55-415v-air-compressor","title":"Puma P55 Air Compressor (265L, 3 Phase)","description":"\u003cstyle\u003e\n.dspp { background:#fff; font-family:'Barlow',sans-serif; color:#2a2a2a; }\n.dspp h2 { font-family:'Saira',sans-serif; font-weight:700; color:#1a1a1a; font-size:20px; margin:30px 0 10px; }\n.dspp h3 { font-family:'Saira',sans-serif; font-weight:600; color:#0f63b3; font-size:16px; margin:20px 0 8px; }\n.dspp p { font-size:15px; line-height:1.7; margin:0 0 12px; }\n.dspp-lead { font-size:16px; line-height:1.75; margin:0 0 18px; }\n\n.dspp-badges { display:flex; gap:8px; flex-wrap:wrap; margin:0 0 22px; }\n.dspp-badge { background:#eaebfd; color:#0f63b3; font-family:'Saira',sans-serif; font-weight:600; font-size:12.5px; padding:7px 13px; border-radius:6px; border:1px solid #d8daff; }\n.dspp-badge-hero { background:#0f63b3; color:#fff; border-color:#0f63b3; }\n.dspp-badge-power { background:#fdecec; color:#c81e21; border-color:#f5c6c6; }\n.dspp-badge-free { background:#e1f5ee; color:#0f6e56; border-color:#a8ddc9; }\n\n.dspp-snapshot { background:#f8faff; border:1px solid #d8daff; border-radius:8px; padding:16px 18px; margin:0 0 24px; }\n.dspp-snapshot-row { display:flex; gap:12px; padding:9px 0; border-bottom:1px solid #e8ebff; font-size:14px; line-height:1.55; }\n.dspp-snapshot-row:last-child { border-bottom:none; }\n.dspp-snapshot-row strong { font-family:'Saira',sans-serif; color:#0f63b3; flex-shrink:0; min-width:112px; font-size:13.5px; }\n\n.dspp-cols { display:grid; grid-template-columns:1fr 1fr; gap:16px; margin:12px 0 20px; }\n@media (max-width:560px){ .dspp-cols { grid-template-columns:1fr; } }\n.dspp-box { border:1px solid #d8daff; border-radius:8px; padding:15px 17px; }\n.dspp-box.dspp-yes { background:#f4fbf8; border-color:#0f6e56; }\n.dspp-box.dspp-no { background:#fdf7f7; border-color:#e0b4b4; }\n.dspp-box h4 { font-family:'Saira',sans-serif; font-weight:600; font-size:12.5px; text-transform:uppercase; letter-spacing:.04em; margin:0 0 9px; }\n.dspp-box.dspp-yes h4 { color:#0f6e56; }\n.dspp-box.dspp-no h4 { color:#c04545; }\n.dspp-box ul { margin:0; padding-left:17px; }\n.dspp-box li { font-size:13.5px; line-height:1.6; }\n\n.dspp-table { width:100%; border-collapse:collapse; margin:12px 0 18px; }\n.dspp-table th { background:#0f63b3; color:#fff !important; text-align:left; padding:10px 12px; font-family:'Saira',sans-serif; font-weight:600; font-size:13px; }\n.dspp-table td { padding:10px 12px; border-bottom:1px solid #d8daff; font-size:14px; vertical-align:top; }\n.dspp-table tr:nth-child(even) td { background:#f5f6ff; }\n.dspp-table td:first-child { font-weight:600; color:#1a1a1a; width:38%; }\n.dspp-ctx { display:block; color:#6c6e7a; font-size:12.5px; margin-top:3px; line-height:1.45; }\n\n.dspp-rate { font-family:'Saira',sans-serif; font-weight:700; font-size:13px; }\n.dspp-rate-exc { color:#0f6e56; }\n.dspp-rate-sui { color:#0f63b3; }\n.dspp-rate-chk { color:#8a5a00; }\n\n.dspp-why { display:grid; grid-template-columns:repeat(auto-fit,minmax(230px,1fr)); gap:14px; margin:14px 0 20px; }\n.dspp-why-card { border:1px solid #d8daff; border-radius:8px; padding:15px 16px; background:#fff; }\n.dspp-why-card h4 { font-family:'Saira',sans-serif; font-weight:600; color:#0f63b3; font-size:14px; margin:0 0 5px; }\n.dspp-why-card p { font-size:13px; line-height:1.55; margin:0; color:#4a4a4a; }\n\n.dspp-fad { background:#eaebfd; border-radius:8px; padding:18px 20px; margin:14px 0 22px; }\n.dspp-fad h3 { margin-top:0; }\n.dspp-fad p { font-size:14px; line-height:1.65; margin:0 0 10px; }\n.dspp-fad p:last-child { margin-bottom:0; }\n.dspp-fad strong { color:#0f63b3; font-family:'Saira',sans-serif; }\n\n.dspp-install { border-left:4px solid #0f63b3; background:#f8faff; padding:16px 18px; margin:14px 0 20px; border-radius:0 6px 6px 0; }\n.dspp-install ul { margin:8px 0 0; padding-left:18px; }\n.dspp-install li { font-size:14px; line-height:1.7; }\n\n.dspp-choose-item { padding:10px 0; border-bottom:1px solid #e8ebff; font-size:14px; line-height:1.6; }\n.dspp-choose-item:last-child { border-bottom:none; }\n.dspp-choose-item strong { font-family:'Saira',sans-serif; color:#1a1a1a; }\n.dspp-choose-item a { color:#0f63b3; font-weight:600; }\n\n.dspp-system { background:linear-gradient(135deg,#0f63b3 0%,#094a85 100%); border-radius:10px; padding:24px; margin:28px 0 20px; }\n.dspp-system h2 { color:#fff !important; margin:0 0 6px; font-size:19px; }\n.dspp-system \u003e p { color:#dbe6f5; font-size:14px; margin:0 0 16px; }\n.dspp-flow { display:flex; flex-wrap:wrap; gap:6px; align-items:center; margin-bottom:16px; }\n.dspp-flow span { background:rgba(255,255,255,.14); color:#fff; font-family:'Saira',sans-serif; font-weight:600; font-size:12.5px; padding:7px 12px; border-radius:5px; }\n.dspp-flow i { color:#8fc0f0; font-style:normal; font-weight:700; }\n.dspp-system-links { display:flex; flex-wrap:wrap; gap:8px; }\n.dspp-system-links a { background:#fff; color:#0f63b3 !important; font-family:'Saira',sans-serif; font-weight:600; font-size:13.5px; text-decoration:none; padding:10px 18px; border-radius:6px; }\n.dspp-system-links a.dspp-ghost { background:transparent; color:#fff !important; border:2px solid rgba(255,255,255,.5); }\n\n.dspp-faq details { border:1px solid #d8daff; border-radius:6px; margin-bottom:7px; }\n.dspp-faq summary { cursor:pointer; padding:12px 15px; font-family:'Saira',sans-serif; font-weight:600; font-size:14px; color:#1a1a1a; list-style:none; }\n.dspp-faq summary::-webkit-details-marker { display:none; }\n.dspp-faq summary:before { content:\"+ \"; color:#0f63b3; font-weight:700; }\n.dspp-faq details[open] summary:before { content:\"\\2013 \"; }\n.dspp-faq .dspp-faq-body { padding:0 15px 13px; font-size:14px; line-height:1.65; color:#4a4a4a; }\n\n.dspp-note { background:#fff5e6; border-left:4px solid #ed2326; border-radius:4px; padding:13px 15px; margin:18px 0; }\n.dspp-note p { color:#8a5a00; font-size:13.5px; margin:0; line-height:1.6; }\n.dspp-disclaimer { border:1px dashed #d8daff; border-radius:6px; padding:12px 15px; margin:18px 0; }\n.dspp-disclaimer p { color:#6c6e7a; font-size:12.5px; margin:0; line-height:1.6; }\n\n.dspp-cta { background:#eaebfd; border-radius:8px; padding:22px; text-align:center; margin:28px 0 8px; }\n.dspp-cta p { font-size:14px; margin:0 0 14px; }\n.dspp-cta a { display:inline-block; background:#0f63b3; color:#fff !important; font-family:'Saira',sans-serif; font-weight:600; text-decoration:none; padding:12px 24px; border-radius:6px; font-size:14px; margin:0 4px 6px; }\n.dspp-cta a.dspp-cta-alt { background:#fff; color:#0f63b3 !important; border:2px solid #d8daff; }\n\u003c\/style\u003e\n\u003cdiv class=\"dspp\"\u003e\n\n\u003cp class=\"dspp-lead\"\u003e\u003cstrong\u003e10 hp \/ 7.5 kW. 1,055 L\/min FAD. 265 litre tank. 415V three phase. Free delivery.\u003c\/strong\u003e The largest Puma we stock. The pump turns at just 750 rpm, and slow-turning pumps run cooler and last longer under the continuous load a busy workshop puts on them.\u003c\/p\u003e\n\n\u003cdiv class=\"dspp-whofor\"\u003e\u003cp\u003eBest Puma compressor for high-volume commercial facilities with several operators working simultaneously across multiple bays.\u003c\/p\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"dspp-badges\"\u003e\n\u003cspan class=\"dspp-badge-hero\"\u003e10 hp \/ 7.5 kW\u003c\/span\u003e\u003cspan class=\"dspp-badge\"\u003e1,055 L\/min FAD\u003c\/span\u003e\u003cspan class=\"dspp-badge\"\u003e265 L tank\u003c\/span\u003e\u003cspan class=\"dspp-badge\"\u003e800 kPa \/ 116 psi\u003c\/span\u003e\u003cspan class=\"dspp-badge-power\"\u003e415V three phase\u003c\/span\u003e\u003cspan class=\"dspp-badge-power\"\u003e25 A breaker\u003c\/span\u003e\u003cspan class=\"dspp-badge-free\"\u003eFree delivery\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"dspp-snapshot\"\u003e\n\u003cdiv class=\"dspp-snapshot-row\"\u003e\n\u003cstrong\u003ePower\u003c\/strong\u003e\u003cspan\u003e415V three phase, 16.1 amps running, 25 amp circuit breaker. Licensed electrician required.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dspp-snapshot-row\"\u003e\n\u003cstrong\u003eWorkload\u003c\/strong\u003e\u003cspan\u003eHigh-volume continuous operation across multiple bays.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dspp-snapshot-row\"\u003e\n\u003cstrong\u003eDelivery\u003c\/strong\u003e\u003cspan\u003ePalletised with free delivery. Confirm access and unloading before ordering.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dspp-snapshot-row\"\u003e\n\u003cstrong\u003eAir quality\u003c\/strong\u003e\u003cspan\u003eOil-lubricated, but a 5 micron filter regulator is fitted as standard. That handles dirt and water. For paint, ceramic coatings or PPF, add a coalescing filter downstream, since a 5 micron element does not remove oil aerosol.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dspp-snapshot-row\"\u003e\n\u003cstrong\u003eWorth knowing\u003c\/strong\u003e\u003cspan\u003eMaximum pressure is 800 kPa (116 psi), lower than the 240V models. Still well above what detailing tools need, but check any equipment with a higher requirement.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eBest suited to\u003c\/h2\u003e\n\u003cdiv class=\"dspp-cols\"\u003e\n  \u003cdiv class=\"dspp-box dspp-yes\"\u003e\n\u003ch4\u003eIdeal for\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-volume commercial detailing and automotive facilities\u003c\/li\u003e\n\u003cli\u003eSeveral operators working simultaneously all day\u003c\/li\u003e\n\u003cli\u003eLarge ring mains with multiple drop points\u003c\/li\u003e\n\u003cli\u003eWorkshops planning for expansion\u003c\/li\u003e\n\u003cli\u003eOperations where compressor downtime is costly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"dspp-box dspp-no\"\u003e\n\u003ch4\u003eNot the right choice if\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou do not have three-phase with adequate switchboard capacity\u003c\/li\u003e\n\u003cli\u003eFewer than three operators, where a P30 is more economical\u003c\/li\u003e\n\u003cli\u003eYou need equipment running above 800 kPa (116 psi)\u003c\/li\u003e\n\u003cli\u003eFloor space or delivery access is restricted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhat it can handle\u003c\/h2\u003e\n\u003ctable class=\"dspp-table\"\u003e\n  \u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003cth\u003eSuitability\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBlow guns\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"dspp-rate dspp-rate-exc\"\u003eExcellent\u003c\/span\u003e\u003cspan class=\"dspp-ctx\"\u003eWell suited to typical blow-gun use.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir blow-out and detailing tools\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"dspp-rate dspp-rate-exc\"\u003eExcellent\u003c\/span\u003e\u003cspan class=\"dspp-ctx\"\u003eAmple headroom across multiple stations.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTornador-style interior guns\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"dspp-rate dspp-rate-exc\"\u003eExcellent\u003c\/span\u003e\u003cspan class=\"dspp-ctx\"\u003eComfortable continuous use.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic polishers\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"dspp-rate dspp-rate-exc\"\u003eExcellent\u003c\/span\u003e\u003cspan class=\"dspp-ctx\"\u003eSustained use across multiple operators.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic sanders\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"dspp-rate dspp-rate-exc\"\u003eExcellent\u003c\/span\u003e\u003cspan class=\"dspp-ctx\"\u003e1,055 L\/min handles sanders comfortably.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiple air tools at once\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"dspp-rate dspp-rate-exc\"\u003eExcellent\u003c\/span\u003e\u003cspan class=\"dspp-ctx\"\u003eDesigned for it. Contact us to confirm your specific combination.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-consumption tools\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"dspp-rate dspp-rate-sui\"\u003eSuitable\u003c\/span\u003e\u003cspan class=\"dspp-ctx\"\u003eCheck the requirement against 1,055 L\/min and 800 kPa maximum pressure.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"dspp-disclaimer\"\u003e\n  \u003cp\u003eRatings above are guidance based on the compressor's Free Air Delivery against typical air consumption for each tool type. They are not a performance guarantee. Actual results depend on your specific tools, working pressure, air line setup and how continuously you run them. Check your tool's air requirement before ordering, or get in touch and we will check it for you.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\u003ch2\u003eWhy choose this Puma\u003c\/h2\u003e\n\u003cdiv class=\"dspp-why\"\u003e\n\u003cdiv class=\"dspp-why-card\"\u003e\n\u003ch4\u003e1,055 L\/min free air delivery\u003c\/h4\u003e\n\u003cp\u003eRoughly double the P30 and three times the largest single-phase Puma.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dspp-why-card\"\u003e\n\u003ch4\u003e265 litre receiver\u003c\/h4\u003e\n\u003cp\u003eA large reserve that smooths out demand spikes when several outlets trigger at once.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dspp-why-card\"\u003e\n\u003ch4\u003e10 hp \/ 7.5 kW motor\u003c\/h4\u003e\n\u003cp\u003eThree-phase, built for continuous industrial duty.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dspp-why-card\"\u003e\n\u003ch4\u003ePuma PG100 pump at 750 rpm\u003c\/h4\u003e\n\u003cp\u003eVery slow turning. Lower pump speed means less heat, less wear and a longer service life.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dspp-why-card\"\u003e\n\u003ch4\u003eCast pump construction\u003c\/h4\u003e\n\u003cp\u003eBuilt for the sustained load of a working commercial facility.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dspp-why-card\"\u003e\n\u003ch4\u003eFree delivery\u003c\/h4\u003e\n\u003cp\u003eShips palletised at no delivery cost.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFAD explained, and why it matters\u003c\/h2\u003e\n\u003cdiv class=\"dspp-fad\"\u003e\n  \u003cp\u003eCompressor air output is quoted two different ways, and the difference catches a lot of buyers out.\u003c\/p\u003e\n  \u003cp\u003e\u003cstrong\u003ePump displacement\u003c\/strong\u003e is the volume the pump sweeps on every rotation. It is a theoretical figure and it is always the larger of the two, which is why it often appears first in marketing.\u003c\/p\u003e\n  \u003cp\u003e\u003cstrong\u003eFree Air Delivery (FAD)\u003c\/strong\u003e is the air that actually reaches your tool once losses through the valves, rings and heat are accounted for. This is the number that determines whether your equipment will run properly.\u003c\/p\u003e\n  \u003cp\u003eWe list FAD as the headline figure on every Puma page. If you are comparing this against another compressor and that one only quotes displacement, you are not comparing like with like. Always ask for the FAD figure.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"dspp-table\"\u003e\n  \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e10 hp \/ 7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump displacement\u003c\/td\u003e\n\u003ctd\u003e1,415 L\/min (50.0 cfm)\u003cspan class=\"dspp-ctx\"\u003eTheoretical figure.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree air delivery (FAD)\u003c\/td\u003e\n\u003ctd\u003e1,055 L\/min (37.3 cfm)\u003cspan class=\"dspp-ctx\"\u003eUse this figure when comparing compressors.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pressure\u003c\/td\u003e\n\u003ctd\u003e800 kPa (116 psi)\u003cspan class=\"dspp-ctx\"\u003eLower than the 240V models but well above typical detailing requirements.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank capacity\u003c\/td\u003e\n\u003ctd\u003e265 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRunning current\u003c\/td\u003e\n\u003ctd\u003e16.1 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit breaker rating\u003c\/td\u003e\n\u003ctd\u003e25 Amps\u003cspan class=\"dspp-ctx\"\u003eRequired breaker size for installation.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump model\u003c\/td\u003e\n\u003ctd\u003ePuma PG100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump speed\u003c\/td\u003e\n\u003ctd\u003e750 rpm\u003cspan class=\"dspp-ctx\"\u003eVery slow turning, which extends pump life.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump type\u003c\/td\u003e\n\u003ctd\u003ePiston, oil-lubricated, belt-driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet size\u003c\/td\u003e\n\u003ctd\u003eContact us\u003cspan class=\"dspp-ctx\"\u003eContact us to confirm before ordering fittings.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003eContact us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eContact us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eContact us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e12 months\u003cspan class=\"dspp-ctx\"\u003eGlenco Air \u0026amp; Power warranty against defects.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelivery\u003c\/td\u003e\n\u003ctd\u003ePalletised, free delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation and ordering\u003c\/h2\u003e\n\u003cdiv class=\"dspp-install\"\u003e\n  \u003cul\u003e\n\u003cli\u003eRequires a 415V three-phase supply. A single-phase workshop cannot run this compressor under any circumstances.\u003c\/li\u003e\n\u003cli\u003eInstallation and connection must be carried out by a licensed electrician.\u003c\/li\u003e\n\u003cli\u003eConfirm your switchboard has spare capacity and the correct breaker rating available before ordering.\u003c\/li\u003e\n\u003cli\u003eThis is a fixed installation, not a portable unit. Decide on its position before delivery.\u003c\/li\u003e\n\u003cli\u003eShips on a pallet. You will need suitable access and a means of unloading, such as a forklift or pallet jack on a level surface.\u003c\/li\u003e\n\u003cli\u003eAllow clear space around the unit for airflow, servicing and access to the tank drain.\u003c\/li\u003e\n\u003cli\u003eFit filtration between the compressor and your air line. For paint, coating or PPF work, include a suitable coalescing filter to reduce oil aerosol.\u003c\/li\u003e\n\u003cli\u003eConfirm your switchboard can support a 25 amp three-phase circuit. This is a substantial electrical load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eChoosing the right Puma\u003c\/h2\u003e\n\u003cdiv class=\"dspp-choose-item\"\u003e\n\u003cstrong\u003eStep down if\u003c\/strong\u003e you have two or three operators rather than a full workshop. The \u003ca href=\"\/products\/puma-p30-415v-air-compressor\"\u003eP30 415V\u003c\/a\u003e delivers 520 L\/min and costs considerably less.\u003c\/div\u003e\n\u003cdiv class=\"dspp-choose-item\"\u003e\n\u003cstrong\u003eStep down to single phase if\u003c\/strong\u003e you do not have three-phase available. The \u003ca href=\"\/products\/puma-p22-120l-240v-air-compressor\"\u003eP22-120L\u003c\/a\u003e is the most capable single-phase option at 350 L\/min.\u003c\/div\u003e\n\u003cdiv class=\"dspp-choose-item\"\u003e\n\u003cstrong\u003ePlanning a full ring main?\u003c\/strong\u003e Use the \u003ca href=\"\/pages\/air-line-configurator\"\u003eAir Line Configurator\u003c\/a\u003e to size your AIRnet pipework and generate a complete parts list.\u003c\/div\u003e\n\n\u003cdiv class=\"dspp-system\"\u003e\n  \u003ch2\u003eBuild a complete compressed-air system\u003c\/h2\u003e\n  \u003cp\u003eA compressor on its own is only the starting point. What reaches your tool depends just as much on filtration and pipework.\u003c\/p\u003e\n  \u003cdiv class=\"dspp-flow\"\u003e\n    \u003cspan\u003eCompressor\u003c\/span\u003e\u003ci\u003e→\u003c\/i\u003e\u003cspan\u003eFiltration\u003c\/span\u003e\u003ci\u003e→\u003c\/i\u003e\u003cspan\u003eAIRnet pipe\u003c\/span\u003e\u003ci\u003e→\u003c\/i\u003e\u003cspan\u003eBall valve\u003c\/span\u003e\u003ci\u003e→\u003c\/i\u003e\u003cspan\u003eHose reel\u003c\/span\u003e\u003ci\u003e→\u003c\/i\u003e\u003cspan\u003eAir tool\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"dspp-system-links\"\u003e\n    \u003ca href=\"\/pages\/air-line-configurator\"\u003eAir Line Configurator\u003c\/a\u003e\n    \u003ca class=\"dspp-ghost\" href=\"\/collections\/airnet\"\u003eAIRnet Piping\u003c\/a\u003e\n    \u003ca class=\"dspp-ghost\" href=\"\/pages\/oil-free-vs-oil-lubricated-vs-silent-air-compressors\"\u003eBuying Guide\u003c\/a\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eMaintenance\u003c\/h2\u003e\n\u003cp\u003eGlenco publish a full maintenance schedule for oil-lubricated compressors. Keeping to it is what determines how many years you get out of the pump.\u003c\/p\u003e\n\u003ctable class=\"dspp-table\"\u003e\n  \u003ctr\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003cth\u003eTask\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDaily\u003c\/td\u003e\n\u003ctd\u003eCheck the oil level and inspect for oil leaks. Drain accumulated condensate from the tank; daily draining is recommended where the compressor is used frequently.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003ctd\u003eCheck or clean the air filter, test the safety valve, inspect for air leaks.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMonthly\u003c\/td\u003e\n\u003ctd\u003eCheck the V-belt, tighten fasteners, clean the unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e3 months or 500 hours\u003c\/td\u003e\n\u003ctd\u003eReplace the oil.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e12 months or 2,000 hours\u003c\/td\u003e\n\u003ctd\u003eReplace the air filter.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e2 years or 4,000 hours\u003c\/td\u003e\n\u003ctd\u003eReplace the filter-regulator and V-belt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"dspp-compare-note\"\u003eConsumables including filters, lubricants and V-belts are not covered by warranty. Service intervals should be shortened in harsher working conditions.\u003c\/p\u003e\n\n\u003ch2\u003eCompare the Puma range\u003c\/h2\u003e\n\u003ctable class=\"dspp-compare\"\u003e\n  \u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eFAD\u003c\/th\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003cth\u003eMax pressure\u003c\/th\u003e\n\u003cth\u003eBest for\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/puma-p14-60l-240v-air-compressor\"\u003eP14-60L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e210 L\/min\u003c\/td\u003e\n\u003ctd\u003e60 L\u003c\/td\u003e\n\u003ctd\u003e240V 10A\u003c\/td\u003e\n\u003ctd\u003e1,000 kPa\u003c\/td\u003e\n\u003ctd\u003eMobile detailing and home garages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/puma-p16-100l-240v-air-compressor\"\u003eP16-100L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e240 L\/min\u003c\/td\u003e\n\u003ctd\u003e100 L\u003c\/td\u003e\n\u003ctd\u003e240V 10A\u003c\/td\u003e\n\u003ctd\u003e800 kPa\u003c\/td\u003e\n\u003ctd\u003eMost air available on a standard 10A outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/puma-p18-100l-240v-air-compressor\"\u003eP18-100L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320 L\/min\u003c\/td\u003e\n\u003ctd\u003e100 L\u003c\/td\u003e\n\u003ctd\u003e240V 15A\u003c\/td\u003e\n\u003ctd\u003e1,000 kPa\u003c\/td\u003e\n\u003ctd\u003eWhen you need 145 psi on single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/puma-p22-100l-240v-air-compressor\"\u003eP22-100L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e350 L\/min\u003c\/td\u003e\n\u003ctd\u003e100 L\u003c\/td\u003e\n\u003ctd\u003e240V 15A\u003c\/td\u003e\n\u003ctd\u003e800 kPa\u003c\/td\u003e\n\u003ctd\u003eMost air available on single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/puma-p22-120l-240v-air-compressor\"\u003eP22-120L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e350 L\/min\u003c\/td\u003e\n\u003ctd\u003e120 L\u003c\/td\u003e\n\u003ctd\u003e240V 15A\u003c\/td\u003e\n\u003ctd\u003e800 kPa\u003c\/td\u003e\n\u003ctd\u003eSustained use, largest single-phase tank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/puma-p30-415v-air-compressor\"\u003eP30 415V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e520 L\/min\u003c\/td\u003e\n\u003ctd\u003e140 L\u003c\/td\u003e\n\u003ctd\u003e415V 3ph\u003c\/td\u003e\n\u003ctd\u003e1,000 kPa\u003c\/td\u003e\n\u003ctd\u003eMultiple operators, entry three phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"dspp-this\"\u003e\n\u003ctd\u003eP55 415V\u003c\/td\u003e\n\u003ctd\u003e1,055 L\/min\u003c\/td\u003e\n\u003ctd\u003e265 L\u003c\/td\u003e\n\u003ctd\u003e415V 3ph\u003c\/td\u003e\n\u003ctd\u003e800 kPa\u003c\/td\u003e\n\u003ctd\u003eHigh-volume multi-bay workshops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"dspp-compare-note\"\u003eFree air delivery is the figure to size your tools against. Higher pressure and higher flow are a trade-off at each amp rating, so pick based on what your tools actually require.\u003c\/p\u003e\n\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdiv class=\"dspp-faq\"\u003e\n\u003cdetails\u003e\u003csummary\u003eHow much air does it deliver?\u003c\/summary\u003e\u003cdiv class=\"dspp-faq-body\"\u003e\u003cp\u003e1,055 L\/min free air delivery (37.3 cfm). Pump displacement is 1,415 L\/min (50.0 cfm), but FAD is the usable figure.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat does FAD mean?\u003c\/summary\u003e\u003cdiv class=\"dspp-faq-body\"\u003e\u003cp\u003eFree Air Delivery. It is the air actually reaching your tools after internal losses, as opposed to pump displacement which is theoretical. On this model the gap is 360 L\/min, which shows why the distinction matters.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat tools can it run?\u003c\/summary\u003e\u003cdiv class=\"dspp-faq-body\"\u003e\u003cp\u003eAnything used in a commercial detailing or automotive workshop, including multiple pneumatic sanders and polishers running at once. Check any equipment requiring more than 800 kPa (116 psi).\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eHow many tools can operate simultaneously?\u003c\/summary\u003e\u003cdiv class=\"dspp-faq-body\"\u003e\u003cp\u003eWe do not publish a fixed number because it depends on the specific tools, their duty cycle and your pipework. Send us your equipment list and workshop layout and we will size the whole system.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat power supply is required?\u003c\/summary\u003e\u003cdiv class=\"dspp-faq-body\"\u003e\u003cp\u003e415V three phase, 16.1 amps running with a 25 amp circuit breaker. A licensed electrician must carry out the connection and your switchboard needs spare capacity.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhy is the maximum pressure lower than the smaller models?\u003c\/summary\u003e\u003cdiv class=\"dspp-faq-body\"\u003e\u003cp\u003eThis model is rated to 800 kPa (116 psi) rather than the 1,000 kPa (145 psi) of the 240V range. Detailing tools typically run at 600 to 800 kPa, so it remains well within requirements, but check any high-pressure equipment such as truck tyre inflation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eIs it suitable for detailing?\u003c\/summary\u003e\u003cdiv class=\"dspp-faq-body\"\u003e\u003cp\u003eYes, for high-volume operations. Pair it with proper filtration, as this is an oil-lubricated compressor and oil carryover will contaminate paintwork, ceramic coatings and PPF.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eIs delivery included?\u003c\/summary\u003e\u003cdiv class=\"dspp-faq-body\"\u003e\u003cp\u003eYes, palletised with free delivery. Confirm access and unloading arrangements before ordering.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes it need professional installation?\u003c\/summary\u003e\u003cdiv class=\"dspp-faq-body\"\u003e\u003cp\u003eYes. Three-phase connection must be carried out by a licensed electrician, and the unit needs positioning before delivery given its size.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat warranty comes with it?\u003c\/summary\u003e\u003cdiv class=\"dspp-faq-body\"\u003e\u003cp\u003eGlenco Air \u0026amp; Power provide a 12 month warranty against defects in material and workmanship from the date of original sale. Electric motors carry whatever warranty the motor manufacturer provides. Consumables including filters, lubricants and V-belts are not covered, nor is normal wear and tear. Keep your tax invoice as proof of purchase.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat maintenance does it need?\u003c\/summary\u003e\u003cdiv class=\"dspp-faq-body\"\u003e\u003cp\u003eGlenco publish a full schedule. Daily: check the oil level, inspect for oil leaks and drain the air tank. Weekly: check or clean the air filter, test the safety valve and inspect for air leaks. Monthly: check the V-belt, tighten fasteners and clean the unit. Every 3 months or 500 hours: replace the oil. Every 12 months or 2,000 hours: replace the air filter. Every 2 years or 4,000 hours: replace the filter-regulator and V-belt.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"dspp-cta\"\u003e\n  \u003cp\u003eNot sure which Puma compressor is right for your tools? Compare the range above, or use our Air Line Configurator to size the whole system.\u003c\/p\u003e\n  \u003ca href=\"\/pages\/air-line-configurator\"\u003ePlan Your Air Line\u003c\/a\u003e\n  \u003ca class=\"dspp-cta-alt\" href=\"\/collections\/puma\"\u003eCompare All Puma Compressors\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Puma","offers":[{"title":"Default Title","offer_id":49745495490775,"sku":"PU P55 415V","price":5939.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0005\/5486\/0601\/files\/PU-P55-415V-centre_22035a7e-1c80-4e10-b913-f10f123662a8.jpg?v=1788732398","url":"https:\/\/detailingshed.com.au\/products\/puma-p55-415v-air-compressor","provider":"Detailing Shed","version":"1.0","type":"link"}