Search

Search our shop

Westinghouse iGen4750PRO Inverter Generator 3,800W Pure Sine Wave

WP iGen4750PRO

Options: iGen4750PRO
✓
In-stock: Inventory updated

The Westinghouse iGen4750PRO is the entry point into the PRO range and the one most mobile detailers start with. It gives you 3,800 running watts through a single 15 amp weatherproof outlet, with an RCD safety switch built into the control panel. That is enough to run one machine properly: a Kranzle pressure washer, a BigBoi blower, or a small air compressor. At 36 kg dry it is the only unit in the range one person can realistically load into a van on their own.

Pure sine wave inverter3,800 running watts57 dB(A) at 1/4 loadOne machine at a time
Power3,800 running watts, 4,750 starting watts, 15.8 amps continuous. Enough for any single 10 or 15 amp detailing machine.
OutletsOne 240V 15 amp IP66 socket, the same 15 amp outlet fitted to every PRO model. A 10 amp plug fits a 15 amp socket, so your detailing gear plugs straight in.
SafetyRCD safety switch fitted, approved for workplace use. Weatherproof IP66 outlet and a frame earthing terminal.
Noise57 dB(A) at quarter load, 67 dB(A) at full load, measured at 7 metres. Quiet enough for a customer's driveway.
Run timeUp to 14 hours at quarter load on a 12 litre tank. 4.2 hours flat out.
Weight36 kg dry, 46 kg with oil and fuel. Extendable handle and wheels.

Who this model suits

Ideal for

  • Solo mobile detailers running one machine at a time
  • Powering a 10 amp or 15 amp Kranzle away from mains
  • Driveway and car park work where noise matters
  • Anyone who loads and unloads the generator single-handed
  • Backup power for a fixed detailing bay during outages

Not the right choice if

  • You need a compressor and a pressure washer running together
  • You want a second outlet for other equipment
  • You run a machine hard all day and want capacity in reserve
  • You want room to add equipment later without changing generators

What it will run

Australian machines are either 10 amp or 15 amp. Power quality is not the limiting factor here, since all three PRO generators give pure sine wave output with less than 2.5% total harmonic distortion. What limits you is the single 15 amp socket, and the 4,750 starting watts available to get a motor turning. Allow two and a half times a motor's rating for starting, or three times for an air compressor that starts against tank pressure rather than venting its head pressure when it stops.

Equipment Supply it needs On the iGen4750PRO
Kranzle KHD7/122TS 10 amp Runs comfortably
Kranzle KHD10/122TS 10 amp Runs comfortably
Kranzle KHD10/122 TST 15 amp, 1.8 kW Runs comfortably
Kranzle K1152TST 15 amp, 2.8 kW intake Needs about 7,000 W to start. Use the iGen7500PRO
BigBoi WashR Tradie 10 amp, 1800 W peak Runs comfortably
BigBoi WashR Flo V2 10 amp, 1600 W peak Runs comfortably
BigBoi BlowR PRO+ MKII 10 amp, two 1600 W motors Runs comfortably
Chicago Pneumatic Whisper 2-50 compressor 10 amp, 1.5 kW Runs comfortably
Chicago Pneumatic CPRC 2.5-50 compressor 10 amp, 1.86 kW Runs. Starting needs 4,650 W, or 5,580 W if it starts under pressure
Pressure washer plus blower together 20 A of supply Not supported, one machine at a time
Pressure washer plus compressor together 20 to 25 A of supply Not supported, step up to the iGen10000PRO
Machine plus lights or a battery charger Under 15 A combined Possible if the total stays under 15 A. Not a second motor load

Where the 15 amp outlet sits against your gear

Single 15 A outlet limit15 A

Any 10 amp machine10 A

Any 15 amp machine15 A

Two machines together20 to 25 A

Bars are scaled against 35 amps so this chart lines up with the iGen7500PRO and iGen10000PRO charts. The generator supplies 15.8 amps continuous through one 15 amp socket, which is why this is a one machine generator. Two motor loads is a job for the iGen10000PRO.

Before you order: Petrol generators must be run outdoors in open air. Never run one inside a van, trailer, garage or any enclosed space, and keep the exhaust away from open doors and windows. Carbon monoxide is odourless.

This generator is not suitable for connection to a fixed multiple earthed neutral (MEN) electrical installation. It is designed for standalone plug and socket use. Any connection to a building's wiring must be done by a licensed electrician with the correct changeover equipment.

Specifications

Specification Detail
Maximum starting power 4,750 W
Continuous running power 3,800 WRated output at 1.0 power factor.
Continuous running current 15.8 A
Output 240V, 50 Hz, single phase
Receptacles 1 x 15 A, IP66A standard 10 amp plug fits a 15 amp socket.
Voltage and waveform control Digital inverter, pure sine wave output
Total harmonic distortion Less than 2.5%Safe for electronically controlled equipment.
RCD safety switch Yes, approved for workplace use
Alternator Brushless, permanent magnetNo brushes to wear out or replace.
Engine 190 cc, 1 cylinder, 4 stroke, overhead valve, air cooled
Maximum engine speed 4,500 rpm
Fuel Unleaded petrol, 91, 95 or 98 RONEthanol blends such as E10 are not recommended.
Fuel tank capacity 12 litres
Run time at 1/4 and full load 14 hours / 4.2 hours
Noise level at 1/4 and full load 57 / 67 dB(A) at 7 m
Oil capacity and viscosity 600 mL, SAE 10W-30
Low oil shutdown and alarm Yes
Starting method Local and remote electric, plus recoil backup
Battery 12V, maintenance free, with plug-in charger
Overload protection Electronic, with indicator and push button reset
Data centre display Output voltage and frequency, current and cumulative run times
Control panel lights LED, operable at all times
Spark plug Torch F7RTC
Generator dimensions (L x W x H) 660 x 374 x 574 mm
Weight, dry / wet 36 kg / 46 kg
Packed dimensions and weight 750 x 460 x 588 mm, 42 kg
Product code WP iGen4750PRO
Warranty 2 year domestic use, conditions apply

How it compares to the other two PRO models

Every PRO model has the same 15 amp IP66 outlet and the same RCD safety switch, so your leads and machines plug in identically whichever one you choose. What changes is how many outlets there are and how much capacity sits behind them.

iGen4750PRO iGen7500PRO iGen10000PRO
3,800 running watts 6,000 running watts 8,200 running watts
15.8 A continuous 25 A continuous 34.2 A continuous
One 15 amp outlet Two 15 amp outlets Two 15 amp outlets and 12V DC
One machine at a time One machine with large reserve Compressor and washer together
36 kg dry 60 kg dry 85 kg dry
12 L tank, 14 h at 1/4 load 15 L tank, 14.6 h at 1/4 load 30 L tank, 19.8 h at 1/4 load
Choose this one if you run a single machine at a time, work alone, and lift the generator in and out of the van yourself.
Step up if you need a compressor and a pressure washer running together. That is the iGen10000PRO, the only model in the range we rate for two machines. The iGen7500PRO sits between the two: still one machine, but with a large reserve, a 32 amp socket and a bigger tank.
Not sure? Read the Westinghouse generator comparison and sizing guide to work out your total draw before you buy.

Common questions

Will it run a Kranzle pressure washer?

 

How much starting power does my machine need?

 

Can I plug a 10 amp lead into the 15 amp outlet?

 

Can I run two machines at once?

 

What does the RCD safety switch actually do?

 

How loud is it in a residential street?

 

Can I connect it to my house or workshop switchboard?

 

What fuel does it take and how long does a tank last?

 

What is included?

 

Equipment suitability above is general guidance based on the manufacturer's published supply requirements for each machine, not a performance guarantee. Actual results depend on your equipment, lead length and condition, ambient temperature, altitude and how continuously you run the load. Specifications are supplied by Westinghouse Outdoor Power Equipment and are subject to change without notice. If you are unsure whether this generator suits your setup, contact us with a list of your machines before ordering.

Not sure which model matches your van setup?

Compare All Three Models Ask Us Before You Buy